Jump To:
All service providers certified to test backflow assemblies within the City of Raleigh's water service area are required to register with the Cross Connection Program prior to submitting a test report per Raleigh City Code Article D-Water Quality Protection.
All reports must be submitted in accordance with the testing schedule and requirements outlined in Public Utilities Handbook Appendix A: Guidelines and Requirements for the Cross Connection Program.
Register as a City of Raleigh Certified Tester
If you wish to test in our water service area, you must be certified by the City of Raleigh's Certification School or one of our approved schools and attend a City of Raleigh orientation session. Acceptance of your test reports cannot be made until you have successfully attended an orientation session and completed all paperwork to verify your certification.
Currently registered as a City of Raleigh Certified Tester?
To continue testing in our water service area, you are responsible to keep our records current with any renewals of your backflow certification and test kit calibrations. Test reports will not be accepted when submitted by testers with expired certificates.
Orientation
Orientation Class:
Cost: $25*
Time: 8:30 to 9:30 a.m.
2025 Orientation Schedule
To reserve a seat please send the Registration Form to Cross.Connection@raleighnc.gov
Dates | Availability |
January 15 | Closed |
February 19 | Closed |
March 19 | Closed |
April 16 | Closed |
May 21 | Open |
June 18 | Open |
July 16 | Open |
August 20 | Open |
September 17 | Open |
October 15 | Open |
November 19 | Open |
December 10 | Open |
2025 NCRWA Schools hosted by Raleigh Water.
For more information and availability contact NCRWA.
The City of Raleigh will accept certifications from the following schools:
City of Durham Department of Water Management
101 City Hall Plaza
Durham, NC 27701
919-560-4194 Ext. 35249
Durham's Backflow Prevention Program
Charlotte-Mecklenburg Utilities Department
5100 Brookshire Blvd.
Charlotte, NC 28216
704-399-2426 Ext. 295
Central Piedmont Community College Construction Education
Greenville Utilities Commission Water Resources Department
PO Box 1847
Greenville, NC 27835
252-551-3399
Greenville Utilities
North Carolina Rural Water Association
P.O. Box 540
Welcome, NC 27374
919-812-2940
NCRWA Backflow Cross Connection Training
Approved Testing Equipment
The purchase of a bleeder valve kit and vertical tube kit is required for performing the Double Check Valve Assembly Test. These kits are available from the equipment manufacturer.
Brand | Model |
---|---|
Apollo/Conbraco | 40-200-TKU |
Apollo/Conbraco | 40-200-TK5U |
Duke | EZ 900 |
Mako | MK5 Digital 5 |
Midwest | 830 |
Midwest | 835 |
Midwest | 844 |
Midwest | 845 |
Watts | TKDL |
Watts | TK-99D |
Watts | TK-99E |
Test Kit Calibration Centers
Test kit calibration is required on an annual bases.
Bavco Backflow Apparatus & Valve Co.
For Watts and Duke Test Kits
20435 South Suzanna Rd
Long Beach, CA 90810
800-458-3492
Nicholson Lab Inc.
For Watts and Duke Test Kits
1423 Queen City Ave
Cincinnati, OH 45214
513-251-8378
Specialty Valve & Controls Company
For Midwest Test Kits
3001 Griffith St
Charlotte, NC 28203
704-522-9873
Precision Measurements Corporation
553-E Pylon Drive
Raleigh, NC 27606
919-755-0382
Approved Backflow Assemblies
Article D: Water Quality Protection and Appendix A: Guidelines and Requirements for the Cross Connection Program states that all containment backflow assemblies shall be approved by the Foundation for Cross Connection Control and Hydraulic Research (FCCHR or USC).
List of approved backflow assemblies allowed for 'new' and 'replacement' backflows in the City of Raleigh's water service area.